Symptoms
Periodic task Clean up expired HTTP Messenger messages fails with one of the following outputs:
The remote server is down, details:
system exception, ID 'IDL:omg.org/CORBA/OBJECT_NOT_EXIST:1.0'
OMG minor code (2), described as 'Failed to create or locate Object Adapter.', completed = NO
or
Named function 'taskCleanupExpiredMessages' is not registered.
Cause
In Operations Automation 7.0 some service controllers have been moved from pem
service to the pau
service.
However, periodic task Clean up expired HTTP Messenger messages tries to call service controller HTTPMessenger
, belongs to pem
and fails to find it.
This behavior has been reported as software-related issue #POA-107130: "7.1: "Clean up expired HTTP Messenger messages" periodic task still try to use "HTTPMessenger" in OA 7.0".
Resolution
Please, contact your Technical Account Manager or Pooled Technical Associate Team (pta@odin.com) in order to trace the status of the issue.
As a temporary solution the task Clean up expired HTTP Messenger messages may be cancelled. To cancel the task perform the following steps:
- Go to OA > Operations > Tasks > Periodic
- Click the task Clean up expired HTTP Messenger messages
- Click Cancel Task and confirm.